Test and Measurement sales: +44 (0) 1928 597200 / tm_sales@uk.yokogawa.com
Other sales: +44 (0) 1928 597100 / other_sales@uk.yokogawa.com

Data Aquisition

Chart Recorders

LR 4000/6000/8000

View Chart Recorder Selection Guide

  • One, two, three, or four-pen model
  • Universal input voltages, thermocouples, or RTDs
  • Crisp, color recording and a wealth of printing functions
  • High reliability owing to non-contact technologies
  • IC memory card (standard), floppy disk drive (optional)

Specification

  • Operating method: digital servo
  • Number of channels: 1,2,3 or 4
  • Input mode: guarded floating input
  • Measurement accuracy: 0.05% of reading + 0.03% of range + 1.0 µV (for 1mV or more voltage range)
  • Measuring range: 0.1 mV to 200 V FS (high sensitivity model), 12 types of thermocouples, and RTDs
  • Measurement cycle: 135 Hz at fastest
  • Chart speed: 10 to 1200 mm/h or mm/min
  • Chart paper: effective recording width of 250mm; fan-folded, 20 m long
  • Recording pen: disposable felt-pen
  • Pen gap: about 4mm, provided with phase sychronization function as standard
  • Printing: wire dot, ink-ribbon (monochromatic)
  • Display: fluorescent display tube (5 by 7dots); 4 lines with 20 characters each
  • Display contents: digital values, bar graph and range
  • Memory: IC card slot (standard), floppy disk drive (optimal)
  • Power supply: AC to DC (optimal)
  • Option: remote control, 4 alarm point output, communication (via GP-IB or RS-232C), floppy disk drive, computation, 10 to 32 V DC drive
  • Dimension: Approx 438 (W) 199 (H) 323 (D) mm
  • Weight: Approx 14 kg (for 4 pens)

LR4200E Flat-Bed Laboratory Recorder Features

  • One, two, three, or four-pen model
  • Universal input voltages, thermocouples, or RTDs
  • Crisp, color recording and a wealth of printing functions
  • High reliability owing to non-contact technologies
  • IE memory card (standard)

Specifications

  • Operating method: digital servo
  • Number of channels: 1, 2, 3 or 4
  • Input mode: guarded floating input
  • Measurement accuracy: 0.05% of reading + 0.03% of range + 1.0 µV( for 1 mV or more)
  • Measuring range: 0.2 mV to 200 V FS (high sensitivity model), 12 types of thermocouples, and RTDs
  • Measurement cycle: 135 hZ at fastest
  • Chart speed: 10 to 1200 mm/h or mm/min
  • Chart paper: effective recording width of 250 mm; fan-folded, 20 m long
  • Pen gap: about 4mm, provided with phase synchronization function as standard
  • Printing: wire dot, ink-ribbon (monochromatic)
  • Display: fluorescent display tube (5 by 7 dots); 4 lines with 20 characters each
  • Display contents: digital values, bar graph, range
  • Memory: IC card slot (standard)
  • Power supply: AC
  • Otion: remote control, 4 alarm point output, communication (via GP-IB or RS-232C), computation, roll chart, re-roll function
  • Dimension: Approx 448 (W) x 455 (D) x 185 (H) mm
  • Weight: Approx 14 kg (with 4 pens)

Download PDF

µRSeries

View Chart Recorder Selection Guide

µR10000 Intelligent Industrial Recorder (100 mm recording chart)

µR10000 has carried over µR series high reliability and basic functions. The 101 x 16 full-dot matrix display allows it to monitor various on-site data.

  • High reliability and high quality
  • Fully contact-less technology
  • High degree of integration using custom IC
  • Light weight (2.5 kg for 6 dot-model)
  • Dust and splash proof front door
  • Variety of line-up
  • 1 to 4 pen model, 6 dot model
  • Variety of input types
  • Universal inputs
  • Many input sensors available (35 input types such as PT50, PR20-40 etc)
  • Superior ease-of-operation
  • VFD 101 x 16 full dot matrix display
  • Versatile operation display
  • Easily navigable interactive setting
  • New chart cassette
  • White LED
  • Analog record of computed result (with the computation option: /M1)
  • Network function
  • Ethernet, RS422A/485 communication option

µR20000 Intelligent Industrial Recorder (180 mm recording chart)

µR20000 has carried over µR series high reliability and basic function. The 181 x 16 fulldot matrix display allows it to monitor various on-site data.

  • High reliability and high quality
  • Fully contact-less technology
  • High degree of integration using custom IC
  • Light weight (8.4 kg for 6 dot-model)
  • Dust and splash proof front door
  • Variety of line-up
  • 1, 2, 3, 4 pen models, 6, 12, 18, 24 dot models
  • Variety of input types
  • Universal inputs
  • Many input sensors available (35 input types such as PT50, PR20-40 etc)
  • Superior ease-of-operation
  • VFD 181 16 full dot matrix display
  • Versatile operation display
  • Easily navigable interactive setting
  • White LED
  • Analog record of computed result (with the computation option: /M1)
  • Network function
  • Ethernet, RS4224A/485 communication option

Download PDF

DR series Hybrid Recorder

View Chart Recorder Selection Guide

  • The DR230 hybrid recorder provides excellent function expandability and design freedom as an R&D tool for all industries, for applications range from small-scale data logging up to multi-point data collection.
  • Superior design freedom - The DR230 provides flexibility to change or expand from small-scale data logging up to multi-point data collection. The DR230 is available as a simple 30-channel (maximum) standalone model and an expandable model that can be expanded from 10 to 300 channels directly by the user.
  • Networking capability - The DR230 can be equipped with an Ethernet (10BASE-T) part so you can build a simple network or connect to an on-premises LAN for remote data acquisition and centralized data management.
  • An economically sensible choice - Remote measurement at distances up to 500 meters reduces wiring requirements, and the units small size helps you save space.
  • High-speed, high-precision measurements - The DR230 is capable of high-speed, high-precision measurements with a scanning speed of 300 channels per 500 ms.
  • PC-friendly - You can easily create a PC-based data acquisition environment. In addition, a floppy drive can be added
  • Wide variety of I/O modules - A wide variety of input modules are available, including voltage, temperature (thermocouple, RTD), contact, strain, pulse, power monitor, and mA (DC current). The large array of module also includes a communication module and alarm output module.
  • Inputs - Standalone model: 10, 20 or 30 channels (specify when ordering) - Expandable model: 10 to 300 channels (can be expanding or changed)
  • Input types: DC voltage, thermocouples, RTD, mA, pulse, power monitor, distortion, DI
  • Communication standards: GP-IB, RS-232-C, RS422A/485, Ethernet
  • Other: Alarm output, remote function
  • Remote measurement (expandable model): Maximum total distance using special cables: 500 meters
  • Maximum number of connected subunits: 6
  • Measurement interval: 0.5 second (expandable model) to 60 seconds (measurement interval range for standalone model starts at 2 seconds)
  • Recording interval: Minimum 2 seconds
  • Recording specifications: 10-color dot recording, 250mm effective recording width
  • Display: VFD 5 x 7 dot matrix, 3-line display
  • Memory: 3.5 inch floppy drive with 512 KB SRAM
  • Options: computation function, report computation function
  • PC software: DAQ 32Plus, DAQLOGGER
  • Dimension: Standalone - approx. 438 (W) x 291 (H) x 336 (D) mm, Expandable model - approx. 438 (W) x 291 (H) x 301 (D) mm, Subunit: approx. 422 (W) x 291 (H) x 100 (D) mm
  • Weight: approx. 13 kg (with module attached)

Download PDF